Electrolux EOB5750AOX User Manual page 35

Table of Contents

Advertisement

70
60
520
60
20
14.2 Securing the appliance to
the cabinet
14.3 Electrical installation
The manufacturer is not
responsible if you do not
follow the safety precautions
from the Safety chapters.
This appliance is supplied with a main
plug and a main cable.
min. 550
20
18
590
min. 560
5
3
14.4 Cable
Cable types applicable for installation or
replacement:
H07 RN-F, H05 RN-F, H05 RRF, H05
A
VV-F, H05 V2V2-F (T90), H05 BB-F
B
For the section of the cable refer to the
total power on the rating plate. You can
also refer to the table:
The earth cord (green / yellow cable)
must be 2 cm longer than phase and
neutral cables (blue and brown cables).
548
21
114
589
594
+-1
595
Total power (W)
maximum 1380
maximum 2300
maximum 3680
ENGLISH
35
198
523
Section of the ca‐
ble (mm²)
3 x 0.75
3 x 1
3 x 1.5

Hide quick links:

Advertisement

Table of Contents
loading