Restore to factory settings

The flush-mounted blind actuator can be restore to the
factory settings at any time. Resetting takes place in
5 stages:
Step 1:
Step 2:
Step 3:
Step 4:
Step 5:
66
Remove rocker from rocker adapter.
Hold down the Config button (B) for at
least 4 seconds with a narrow, pointed
object (e.g. a ballpoint pen) until the
LED in button starts to flash slowly.
Now release the button again.
Press the button again for at least 4
seconds until the LED flashes rapidly,
then release the button again.
The device has now been reset to the
initial state.
Now replace the rocker on the rocker
adapter.