Installation may only take place in normal commercial
switch boxes (device boxes) in accordance with DIN
49073-1.
The device may only be operated with adapters and
an associated, fitted switch cover.
7.1 Installing the Homematic flush-mounted
blind actuator
Permitted cable cross sections for connecting to the
flush-mounted actuator are:
Rigid cable
2
[mm
]
0.75 – 1.50
Before installation, please note the serial num-
ber on the device (10 digits, beneath barcode)
and the exact installation location so that you
can set up the device later via the user inter-
face of the Homematic central control unit.
54
Flexible cable with and without
2
ferrule [mm
0.75 – 1.50
]