Input Clip Margin and Output Clip Margin These options set the
level, relative to the maximum (full scale) level, at which a clip
is reported on a channel. When a clip is detected, the entire
channel meter turns red.
To set Input or Output clip margin:
Click in the "dB Below Max" edit box for Input Clip Margin
1
or Output Clip Margin.
Enter a value or drag to change the value and press Enter.
2
The entered value is interpreted as a relative dB value from the
maximum (where "Max" is considered +20 dBVU). For exam-
ple, with the Input Clip Margin set to 6 dB below max (the de-
fault), peak levels within 6 dB of maximum level will trigger a
clip indication
Clip Hold Time and Peak Hold Time These options specify how
long clips and peaks are held. Default is 2 seconds for both
Clip and Peak hold.
Input Safe Switches
The Input Safe Switches let you control two independent Safe
functions: Automation Safe and Solo Safe. Only one of these
Safe functions can be viewed and controlled at a time.
Act as Automation Safes When selected, this option sets the
Safe switches (on the control surface Input Channels and FX
Returns) and Safe buttons (on all on-screen channels) to tog-
gle the Automation Safe status of the corresponding channel.
You can also use Safe Selected mode to toggle the Automation
Safe status of any channel. See "Automation Safing Channels"
on page 181.
Act as Solo Safes Solo Safe applies only to Input Channels
and FX Returns. When selected, this option sets the Safe
switches (on the control surface and on-screen) to toggle the
Solo Safe status of the corresponding channel. See "Solo Bus
Operation" on page 113.
Ethernet Control
Ethernet Control settings let you configure the D-Show ECx
Ethernet Control option (purchased separately) to allow re-
mote control of D-Show over a wireless Ethernet network.
See the ECx Ethernet Control Option Guide.
Lights
Console and LED/Display settings let you adjust the bright-
ness of the following items:
Console Lights Adjust brightness of external lights connected
to the Console Lights connectors on the back panel.
LEDs and Displays Adjust brightness of LED and LCD displays
on the control surface.
56
D-Show Profile Guide
LCD Displays
These options let you customize the behavior of the control
surface LCDs.
Viewing Angle This option lets you configure the Selected
Channel and Snapshots LCD displays for optimum viewing.
Show Channel Strip Value While Moving Fader This option de-
termines what is displayed in the Channel Name display
when a fader is adjusted.
When selected (default), the Channel Name display switches
from showing channel name to showing the value (level)
when a fader is adjusted. When deselected, the Channel Name
displays do not show values when a fader is adjusted.
Control Surface
(D-Show Main Unit and Sidecars Only)
These options let you link or unlink faders and encoders
across Main and Sidecar units. On D-Show Profile systems,
these options are unavailable.
Events
The Events tab of the Options page lets you use the Event List
to customize D-Show buttons, footswitches and General Pur-
pose Interface (GPI)-connected devices. For information, see
Chapter 22, "Events."
Options > Events page
Plug-Ins
The Plug-Ins tab of the Options page is used to install plug-ins
on the D-Show system. The Plug-Ins tab is available on com-
plete D-Show systems only. It is not available in the D-Show
Standalone software. See "Installing and Authorizing
Plug-Ins" on page 145.