How to mount TOF Sensor

TOF Sensor must be mounted on a ceiling with no dealing facing the floor downward.
(90 degree vertically to the floor)
<Note>
TOF sensor must be oriented as Fig 2-1, Fig 2-2, Fig 2-3 and Fig 2-4.
The allow mark on TOF Sensor is indicated in the figures.
This system has the direction sensing function. Wrong orientation may cause false detections,
"One" person may result in "More" person.
Remove the arrow mark sticker on the front of TOF Sensor after mounting TOF Sensor.
The sticker blocks the field of view of the TOF Sensor.
Fig 2-5
<Note>
Make sure that the direction of the arrow of TOF Sensor is same with the arrow of figures of mounting
position.
When mount TOF Sensor, ensure that there is no obstacle in the Sensing Area (139 mm×50 mm) as shown
in the figure below, and keep 30 mm space in the back of TOF Sensor.
*Keep TOF Sensor not free from static electricity to prevent the dust adhesion to a Sensing area.
Fix TOF Sensor with screws (provided).
139
Fig 2-6
15
[mm]