Installer logout

When finish all settings, click the button of "Installer Logout".
When logged out, and the background of the screen becomes gray, and the three buttons will be
disappeared.

3-4 Operation checking

Output
Condition
Stand by
Waiting a start signal
Zero
Start signal & 2 sec later
No one in interlock
One
Start signal & 2 sec later
One person in interlock
More
Start signal & 2 sec later
Two or more persons in interlock
Suspicious
Start signal & 2 sec later
Masking against TOF Sensor
AIR
Something or someone in interlock
After mounting and setting have been made, check the operations as described in Table 3-2.
Each operating condition is described in Table 3-2.
Check the output seeing Indicator LED.
The start signal is generated by the entry door, once the door has been opened and closed.
2 seconds later the output signal is generated.
Then the output states can be checked.
Table 3-2
Indicator LED
Control Box(A3001CB)
Green
continuously
Blue
0.2 sec
Blue
2 sec
Red
2 sec
Blue & Red
2 sec
Green
Blink at 2 Hz