TERRA SWM HGL with direct heating circuit
The TERRA SWM HGL is a modulating heat pump. Therefore, it is possible to provide heating circuits directly
without a storage tank! An additional pump and a mixing valve for the heating circuit is not necessary. The
Hygienik will be provided over the HGL-pipe. An additional expansion tank must be installed in the return of the
heating circuit. The overfl ow valve in the heating circuit must be set to give a proportional fl ow to the number
of closed zone valves.
With this hydraulic and the modulating operation, can be cooled without a cold storage tank. For dew point
monitoring, a room humidity sensor and a dew point switch must be installed.
esigned for cooling mode.
ing and the power output capacity of the
t least 70 % of the minimum cooling
A35°C/W18°C.
inimum flow rate (1.01 m³/h) have to be
y of 2.8 kW have to be ensured or the
one control.
n a suitable location!
Available as an accessory
P
Depth probes
brine circuit
•
The heating emission system has to be fl oor heating. 1/3 of the fl oor circuits has to be opened
always. Area valves must not be installed.
•
At direct heating circuits an overfl ow valve has to be installed to guarantee a minimum fl ow, so
that the heat pump is not clocking.
•
For the size of the expansion tank the capacity of the hygienik tank has to be counted in.
(C) IDM ENERGIESYSTEME GMBH
OS
T
B35
B35
T
T
B33
M16
M73
T
B43
B34
T
T
B36
TERRA SWM HGL
Installation instructions TERRA SWM
7. Hydraulic diagrams
RE
B61
HC(A)
FS
B51
T
Throttle
valve
P
P
(without layer separation plate)
Hydraulic diagrams
HW
B48
T
B42
T
B1
M
M 22
M
M
M
CW
B41
B4
1
T
Hygienik 2.0
31