Disassembly The Cover - iDM TERRA SWM 3-13 HGL P Technical Documentation And Installation Instructions

With navigator 2.0 controller, brine- or groundwater heat pump with inverter-technology
Table of Contents

Advertisement

5. Allgemeine Informationen
installing the electrics
5 .3. Di sa ssem bl y t h e c ove r
Before the electrical connection of the heat pump the
cover has to be removed. First, the front part with the
NAVIGATOR 2.0 touch display has to be dismount.
To remove the front panel, the interlocking device
must be opened with a screw driver or a pointed
object. The interlocking device is behind the white
cover, around 1 cm above the edge of the unit. By
pressing the locking bolt, the lock of the front panel
will be released.
When removing the front panel, make sure that the
connection cable between the control panel and the
motherboard is disconnected.
The cover is fi xed with two screws. After removing
the screws, the cover can be pulled forward. Now,
the cover can be lifted up and the earthing cable can
be removed. Afterwards the connection terminals are
freely accessible.
Consider the note for opening!
Disconnect the cable to the control panel
26
When disassembling the front panel and the control
unit is already connected, make sure that the con-
necting cable between the control unit and the central
unit is only approx. 1.5 m long.
When removing the panel, the connecting cable
should not be exposed to tensile stress. To comple-
tely remove the panel, the connection cable on the
central unit must be unplugged.
Installation instructions TERRA SWM
Remove the fastening screws
Pull the cover forward and remove it
Remove the earthing cable
(C) IDM ENERGIESYSTEME GMBH

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Terra swm 3-13 series

Table of Contents