Perkins 2806J-E18TTA Operation And Maintenance Manual page 25

Industrial engine
Table of Contents

Advertisement

M0109073
Use an appropriate spreader set so that lifting chains
are perpendicular to the engine.
Radiator Only
Detach the radiator, and mounting bracket at the
engine front support. Add eyebolts or lifting brackets
to the threaded holes marked for lifting.
Clean Emission Module (Diesel
Oxidation Catalyst)
Illustration 22
Typical example
Ensure that the correct clothing is worn, refer to this
Operation and Maintenance Manual, "General
Hazard Information".
The weight of the clean emission module (CEM)
when laden is approximately 81 kg (178.5 lb). Two
suitable double looped slings are required to lift the
CEM. Also a suitable hoist will be required to remove
and install the assembly.
The slings must be attached to the CEM in the
positions as shown in illustration 22 .
Ensure that the slings only contact the body of the
CEM. A test lift may be required to achieve the
correct balance of the assembly.
Some applications may require a frame or jig to lift
the CEM. The frame or jig must only be connected to
the cradle of the CEM. Refer to the OEM for more
information.
Product Storage
(Engine and Aftertreatment)
Your Perkins distributor can help in preparing the
engine for extended storage periods.
Some applications, the engine can be equipped with
delayed engine shutdown. Allow at least 2 minutes
after the engine has stopped before you turn the
battery disconnect switch to OFF. During the 2
minutes the engine electronic control module is
active storing information from the engine and
aftertreatment sensors.
Condition for Storage
An engine can be stored for up to 6 months provided
all the recommendation are adhered to.
Engine
1. Clean the engine of any dirt, rust, grease, and oil.
Inspect the exterior. Paint areas that contain paint
damage with a good quality paint.
2. Remove dirt from the air cleaners. Check all seals,
gaskets, and the filter element for damage.
g06452149
3. Apply lubricant to all points in this Operation and
Maintenance Manual, "Maintenance Interval
Schedule".
4. Drain the crankcase oil. Replace the crankcase oil
and change the oil filters. For the proper
procedure, refer to this Operation and
Maintenance Manual.
5. Add Volatile Corrosion Inhibitor (VCI) oil to the
crankcase oil. The volume of VCI oil in the
crankcase oil should be 3 to 4 percent.
Note: If the engine crankcase is full, drain enough
engine oil so the mixture can be added.
6. Remove the air filter elements. Turn the engine at
cranking speed with the throttle control in FUEL
OFF position. Use a sprayer to add a mixture of 50
percent VCI oil and 50 percent engine oil into the
air inlet or turbocharger inlet.
25
Operation Section
Product Storage
i07835008

Advertisement

Table of Contents
loading

Table of Contents