Router Ip Address Setup Requests - Toshiba V Series User Manual

Integrated controller ethernet module, en311
Hide thumbs Also See for V Series:
Table of Contents

Advertisement

4.7 Router IP Address Setup Requests

This section describes how to setup the router IP address from the S controller user
program.
The following is the format of the router IP address setup request.
Router IP address setup request
(using the USEND_T instruction)
The router IP address is setup for the EN311 in standby mode from the user program.
(1) Request command structure and error status
<Request command>
CMD
CMD+1
CMD+2
CMD+3
<Error status>
STATUS
Error status examples
Error status number
-5001(16#EC77)
-5050(16#EC46)
2880(16#B40)
2896(16#B50)
2929(16#B71)
(2) IP address setup procedure
6F8C0904
F
Destination EN311 module slot number
Command (16#0319)
Router IP address
F
=0: Normal completion, ≠ 0: Error status
Command type error
Module error/Initialization in progress
Station mode error
MAC/IP not set up
IP address error
For the address 133. 113. 90. 250
F
CMD+2
85H
CMD+3
5AH
4.7 Router IP Address Setup Requests
0
0
Description
85H. 71H. 5AH. FAH
87
0
71H
FAH
4