ROYTRONIC EXCEL™
Series AD9 Programming Guide
Electronic Metering Pumps
Instruction Manual
Manual No : 2032
Rev.
: E
Rev. Date
: 06/2019

Advertisement

Table of Contents
loading

Summary of Contents for LMI ROYTRONIC EXCEL AD9 Series

  • Page 1 ROYTRONIC EXCEL™ Series AD9 Programming Guide Electronic Metering Pumps Instruction Manual Manual No : 2032 Rev. Rev. Date : 06/2019...
  • Page 3: Table Of Contents

    TABLE OF CONTENTS 1.0 INTRODUCTION....................1 2.0 FEATURES .
  • Page 4 LIST OF ILLUSTRATIONS FIGURE 1. ROYTRONIC EXCEL™ Series AD9 Control Panel ............. . 3 FIGURE 2.
  • Page 5: Introduction

    SPECIFIC PRECAUTIONS SHOULD offers an extensive range of features, including BE TAKEN WHEN WORKING WITH microprocessor control for accurate and flexible ALL LMI METERING PUMPS. PLEASE REFER TO THE ® PRECAUTIONS SECTION, SEC. 1.0, OF THE ROYTRONIC automation in response to instrument signals. The EXCEL™...
  • Page 6: Features

    SECTION 2 - FEATURES 1. Stroke speed adjustment 1-59 SPH (strokes per 11. C o n t i n u o u s n o n - v o l a t i l e m e m o r y hour) to 1-120 SPM (strokes per minute).
  • Page 7: Keypad/Display: Description And Function

    SECTION 3 - KEYPAD/DISPLAY: DESCRIPTION AND FUNCTION 1. POWER Button 2. MODE Button 3. DOWN Button 4. UP Button 5. Graphical Display 6. Stroke Adjustment Knob 7. Pump ON/OFF LED 8. Low-Level Indicator LED Figure 1. ROYTRONIC EXCEL™ Series AD9 Control Panel UP AND DOWN BUTTONS POWER BUTTON...
  • Page 8: Graphical Display

    SECTION 3 - KEYPAD/DISPLAY: DESCRIPTION AND FUNCTION 3.4 GRAPHICAL DISPLAY LOW LEVEL INDICATOR LED A graphical display is used to show the current Low Level Indicator LED will normally be operational state of the pump as well as a variety OFF.
  • Page 9: Operation Of The Series Ad9

    SECTION 4 - OPERATION OF THE SERIES AD9 4.3 PRIMING THE PUMP This pump features EEPROM nonvolatile memory. The pump will always power up in the last used The priming function allows a fixed-time prime mode. When shipped from the factory the pump will period of 60 seconds and enables priming of the power up in the Manual mode (see Sec.
  • Page 10: Locking/Unlocking The Pump

    SECTION 4 - OPERATION OF THE SERIES AD9 4.4 LOCKING/UNLOCKING THE PUMP To unlock a locked pump, depress the DOWN MODE buttons simultaneously for about The pump has several lock modes to prevent 1 second until the Lock Icon disappears in the casual tampering.
  • Page 11: Alarm/Icon Area

    SECTION 4 - OPERATION OF THE SERIES AD9 4.5 ALARM/ICON AREA The upper left portion of every Control Mode Icon/Alarm Area Display contains an icon/alarm notification area, which graphically displays operational information. If no alarm conditions exist, the display will only show configuration information.
  • Page 12 SECTION 4 - OPERATION OF THE SERIES AD9 Alarm Icon Definitions: ICON NAME DESCRIPTION ** = The pump will stop stroking in this condition Table 2. Alarm Icon Definitions Instruction Manual...
  • Page 13: Control Mode Selection Menu

    SECTION 5 - CONTROL MODE SELECTION MENU 5.1 MANUAL MODE (INTERNAL) This menu is used to select the control mode or enter into the advanced configuration menu. There This mode is used when external devices are not are 2 internal control modes and 3 external control being used to control the pump.
  • Page 14: Pulse Multiply Mode (External)

    SECTION 5 - CONTROL MODE SELECTION MENU 5.2 PULSE MULTIPLY MODE (EXTERNAL) 1. Icon/Alarm Area: The icon indicates the pump is in the pulse multiply mode. Depending This mode is used to control the pump with an on advanced pump configuration options and external device connected to the appropriate any alarms/alerts detected, other icons may be contacts of the 5-Pin connector.
  • Page 15: Pulse Divide Mode (External)

    SECTION 5 - CONTROL MODE SELECTION MENU 5.3 PULSE DIVIDE MODE (EXTERNAL) 4. Pulses per Stroke: Number (1-9999) of valid pulses to detect before performing a pump This mode is used to control the pump with an stroke. See Sec. 6.3 to define a valid pulse. external device connected to the appropriate 5.
  • Page 16: Analog Mode (External)

    SECTION 5 - CONTROL MODE SELECTION MENU 5.4 ANALOG MODE (EXTERNAL) 4. Measured Current: Measured current value (0-24.0 mA). This mode is used to control the pump with an 5. Theoretical Flow: The theoretical flow based external device connected to the appropriate on calculated stroke speed, stroke length, and contacts of the 5-Pin connector.
  • Page 17: Programming The Analog Mode Response Curve

    SECTION 5 - CONTROL MODE SELECTION MENU 5.4.1 Programming the Analog Mode Response Curve Plateau Use the UP or DOWN button to move Linear the selection box to the parameter you wish to Area Stroke change. Use the POWER button to toggle to Rate the parameter’s edit mode - a black background indicates the parameter is in edit mode.
  • Page 18: Timed Event Mode (Internal)

    SECTION 5 - CONTROL MODE SELECTION MENU 5.5 TIMED EVENT MODE (INTERNAL) 4. Current Day and Time: The current Day and Time (see below for time format description). With the pump OFF, press the UP or DOWN 5. Stroke Rate: Indicates the stroke speed of the button to view and/or program the timed events pump (1-59SPH or 1-120 SPM) for the currently (see Section.
  • Page 19: Programming Timed Events

    SECTION 5 - CONTROL MODE SELECTION MENU Display Overview: 5.5.1 Programming Timed Events One timed event may be programmed to execute for each of 7 days. Each event has a uniquely Event Enabled Selection Box programmable start time, duration, and stroke rate. Stroke Length Use the UP or...
  • Page 20: Advanced Configuration Menu

    SECTION 6 - ADVANCED CONFIGURATION MENU Use the UP and DOWN buttons to select SET UNITS the desired mode. Push and hold the POWER Use the UP and DOWN buttons to select button for approximately 1 second to select the the desired units.
  • Page 21: Set Batch Mode

    SECTION 6 - ADVANCED CONFIGURATION MENU SET BATCH MODE SET LOCK MODE CONFIGURATION Batch mode applies only to the Pulse Multiply Mode This menu is used to select the desired lock mode (see Section. 5.2). Use the UP and DOWN and to set the pass code;...
  • Page 22: Set Clock

    SECTION 6 - ADVANCED CONFIGURATION MENU Display Overview: SET CLOCK The clock will only be displayed when operating in Timed Event Mode (see Sec. 5.5). Use the UP or Lock Mode Selection Box DOWN button to edit the highlighted parameter. Code Area Use the POWER button to advance to the next...
  • Page 23: Pump Calibration

    SECTION 6 - ADVANCED CONFIGURATION MENU PUMP CALIBRATION Pump calibration will increase the accuracy of No Calibration the various displayed flow rates and volumes. In Single-Point Calibration (see first diagram below), Post Calibration Flow the pump is calibrated to a specific stroke length (% Rated) and flow rate (P1), changing the slope of the flow line as indicated in the diagram.
  • Page 24: Single-Point Calibration Procedure

    SECTION 6 - ADVANCED CONFIGURATION MENU 3. Press the POWER button to begin calibration 6.6.1 Single-Point Calibration Procedure of the pump. The pump will start pulsing. During calibration, accuracy improves as stroke The display will begin counting the strokes count increases. As a result, a minimum of 100 and displaying the accumulated volume.
  • Page 25: Two-Point Calibration Procedure

    SECTION 6 - ADVANCED CONFIGURATION MENU 3. Press the POWER button to begin the 6.6.2 Two-Point Calibration Procedure calibration of point 1. The pump will start pulsing. During calibration, accuracy improves as stroke The display will begin counting the strokes count increases.
  • Page 26 SECTION 6 - ADVANCED CONFIGURATION MENU 6. Press the POWER button. The pump will 8. Use the UP or DOWN buttons to edit the begin pulsing. Adjust the stroke length knob to highlighted volume as necessary. Press the the desired setting for calibration of point 2. Use POWER button when complete.
  • Page 27: Configure Alarm Output

    SECTION 6 - ADVANCED CONFIGURATION MENU 6.7.1 Configure Alarm Output Mask CONFIGURE ALARM OUTPUT Use the UP or DOWN button to select This feature is used to configure the alarm output, the desired alarm to enable/disable. Use the which is indicated on the appropriate contacts POWER button to toggle the associated status of the 6-Pin connector.
  • Page 28: Set Remote Internal-External Mode Input

    SECTION 6 - ADVANCED CONFIGURATION MENU Use the POWER button to toggle to parameter’s SET REMOTE INTERNAL- edit mode. A black background indicates the EXTERNAL MODE INPUT parameter is in edit mode. While in edit mode, use This feature is used to switch from an internal UP and DOWN buttons to set the value.
  • Page 29: Digi-Pulse™ Flow Monitoring Setup

    SECTION 6 - ADVANCED CONFIGURATION MENU Display Overview: DIGI-PULSE™ FLOW MONITORING SETUP This feature is used in conjunction with the LMI ® Function Enabled Selection Box Series FM-ROY-9 Digi-Pulse™ Flow Monitor (refer Indicator to DIGI-PULSE™ Flow Monitor Instructions P/N Missing Pulses 1865).
  • Page 30: Set Percent-Of-Time Operation

    SECTION 6 - ADVANCED CONFIGURATION MENU Display Overview: 6.10 SET PERCENT-OF-TIME OPERATION This feature allows time-based cycling of the Function Enabled pump in Manual, Pulse Divide, and Analog Control Selection Box Indicator Modes. The pump cycles on and off based on Percent-of-Time Cycle Duration the configuration parameters.
  • Page 31: Load Factory Defaults

    SECTION 6 - ADVANCED CONFIGURATION MENU 6.11 LOAD FACTORY DEFAULTS 6.12 VIEW PUMP INFORMATION This feature will return the pump parameters to This feature displays the pump firmware version. their factory default settings. Push the POWER Use the MODE button to return to the advanced button to highlight the confirmation box.