The Series AD9 electronic metering pump SPECIFIC PRECAUTIONS SHOULD offers an extensive range of features, including BE TAKEN WHEN WORKING WITH ALL LMI ® METERING PUMPS. PLEASE REFER TO THE PRECAUTIONS SECTION, SEC. 1.0, OF THE ROYTRONIC automation in response to instrument signals. The EXCEL™...
SECTION 3 - KEYPAD/DISPLAY: DESCRIPTION AND FUNCTION 1. POWER Button 2. MODE Button 3. DOWN Button 4. UP Button 5. Graphical Display 6. Stroke Adjustment Knob 7. Pump ON/OFF LED 8. Low-Level Indicator LED Figure 1. ROYTRONIC EXCEL™ Series AD9 Control Panel UP AND DOWN BUTTONS POWER BUTTON...
SECTION 3 - KEYPAD/DISPLAY: DESCRIPTION AND FUNCTION 3.4 GRAPHICAL DISPLAY LOW LEVEL INDICATOR LED A graphical display is used to show the current operational state of the pump as well as a variety of specialized programming menus. Tank Empty takes priority. The pump will not stroke when in a Tank Empty condition.
SECTION 4 - OPERATION OF THE SERIES AD9 4.3 PRIMING THE PUMP The pump will always power up in the last used see Sec. 5.1 down the NOTE: If the power to the pump is cut less than 15 seconds after the last programmed values have been set, the latest changes will NOT be stored complete, push the in nonvolatile memory.
SECTION 4 - OPERATION OF THE SERIES AD9 4.4 LOCKING/UNLOCKING THE PUMP To unlock a locked pump, depress the The pump has several lock modes to prevent disappears in the casual tampering. For a complete description see below see Sec. 6.4 To enter the unlock pass code, use the Icon/Alarm Area the pass code is incorrect, the pump will remain...
SECTION 4 - OPERATION OF THE SERIES AD9 4.5 ALARM/ICON AREA Icon/Alarm Area which graphically displays operational information. If no alarm conditions exist, the display will only alarm conditions exist, the display will alternate information and showing alarm information. Alarm icon.
Page 12
SECTION 4 - OPERATION OF THE SERIES AD9 Alarm Icon Definitions: ICON NAME DESCRIPTION ** = The pump will stop stroking in this condition Table 2. Alarm Icon Definitions Instruction Manual...
SECTION 5 - CONTROL MODE SELECTION MENU This menu is used to select the control mode or 5.1 MANUAL MODE (INTERNAL) This mode is used when external devices are not modes. In order to operate the pump in an external Display Overview: is selected, use the Stroke Length...
SECTION 5 - CONTROL MODE SELECTION MENU 5.2 PULSE MULTIPLY MODE (EXTERNAL) 1. Icon/Alarm Area: The icon indicates the pump is in the pulse multiply mode. Depending This mode is used to control the pump with an external device connected to the appropriate see Sec.
SECTION 5 - CONTROL MODE SELECTION MENU 5.3 PULSE DIVIDE MODE (EXTERNAL) 4. Pulses per Stroke: This mode is used to control the pump with an stroke. See Sec. 6.3 external device connected to the appropriate 5. Theoretical Flow: The theoretical flow see Sec.
SECTION 5 - CONTROL MODE SELECTION MENU 5.4 ANALOG MODE (EXTERNAL) 4. Measured Current: Measured current value This mode is used to control the pump with an 5. Theoretical Flow: external device connected to the appropriate on calculated stroke speed, stroke length, and see Sec.
SECTION 5 - CONTROL MODE SELECTION MENU 5.4.1 Programming the Analog Mode Response Curve Plateau Linear Area Stroke Rate edit mode, use the Plateau edit mode and save the setting. Plateau Linear Area Stroke Parameter Selected Placed Into Edit Rate Mode Plateau Less than 0.5mA...
SECTION 5 - CONTROL MODE SELECTION MENU 5.5 TIMED EVENT MODE (INTERNAL) 4. Current Day and Time: The current Day and see below for time format description 5. Stroke Rate: Indicates the stroke speed of the see Section. 5.5.1 running event or the next scheduled event. push the 6.
SECTION 5 - CONTROL MODE SELECTION MENU 5.5.1 Programming Timed Events Display Overview: Event Enabled Selection Box Stroke Length Event Start Event Duration Time Calculated Volume Stroke Rate Theoretical Flow indicates the parameter is in edit mode. The Event 1. Selection Box: Indicates the currently selected than going into an edit mode.
SECTION 6 - ADVANCED CONFIGURATION MENU SET UNITS to selected the item and return to the advanced Display Overview: Display Overview: Selection Box Mode Icons Selection Box Arrow Indicator Unit Icons 1. Mode Icons: Each icon represents a different 1. Unit Icons: control mode, as follows: 2.
SECTION 6 - ADVANCED CONFIGURATION MENU SET BATCH MODE SET LOCK MODE CONFIGURATION This menu is used to select the desired lock mode see Section. 5.2 see Sec. 4.4 to activate the lock saving changes. Display Overview: the next digit, and the ON/OFF Icons Selection Box 1.
SECTION 6 - ADVANCED CONFIGURATION MENU Display Overview: SET CLOCK see Sec. 5.5 Lock Mode Selection Box Code Area Lock Configuration Lock Configuration (No Code) (with Code) to the prior parameter. 1. Lock Mode: Display Overview: The icon corresponding to the current lock AM/PM Indicator Hours Seconds...
SECTION 6 - ADVANCED CONFIGURATION MENU PUMP CALIBRATION No Calibration see first diagram below Post Calibration Flow (% Rated) Calibration Region Stroke Length Figure 3. Two-Point Calibration see second diagram below see Sec. 6.6.1 for single-point calibration procedure or Sec. 6.6.2 for two-point calibration procedure menu without making changes.
SECTION 6 - ADVANCED CONFIGURATION MENU 6.6.1 Single-Point Calibration Procedure of the pump. The pump will start pulsing. and displaying the accumulated volume. The stroke length is changed, a error icon will display, the pump will stop, and the stroke count Procedure: whether to are complete.
SECTION 6 - ADVANCED CONFIGURATION MENU 6.6.2 Two-Point Calibration Procedure and displaying the accumulated volume. The stroke length is changed, a error icon will display, the pump will stop, and the stroke count In general, the Procedure: 5. The two. adjustments are complete.
Page 26
SECTION 6 - ADVANCED CONFIGURATION MENU adjustments are complete. The pump will stop display. whether to displaying the accumulated volume. The Instruction Manual...
SECTION 6 - ADVANCED CONFIGURATION MENU 6.7.1 Configure Alarm Output Mask CONFIGURE ALARM OUTPUT which is indicated on the appropriate contacts navigate using the to indicate whether the pump is in an internal output menu. or external control mode. If the alarm output is Display Overview: Selection Box external mode status, then open contacts indicates...
SECTION 6 - ADVANCED CONFIGURATION MENU SET REMOTE INTERNAL- EXTERNAL MODE INPUT This feature is used to switch from an internal control mode to an external control mode remotely connector. There are two internal control modes see Sec. 5.0 when the contacts are switched from open to closed, or vice versa.
SECTION 6 - ADVANCED CONFIGURATION MENU Display Overview: DIGI-PULSE™ FLOW MONITORING SETUP ® Function Enabled Selection Box Indicator Missing Pulses signal output for each successful pump stroke 1. Function Enabled Indicator: 2. Missing Pulses: least sensitive. 3. Selection Box: Indicates the currently selected item.
SECTION 6 - ADVANCED CONFIGURATION MENU Display Overview: 6.10 SET PERCENT-OF-TIME OPERATION Function Enabled Selection Box Indicator Percent-of-Time Cycle Duration 1. Function Enabled Indicator: Indicates if 2. Percent of Time (Function ON only): 3. Cycle Duration (Function ON only): Total 4.
SECTION 6 - ADVANCED CONFIGURATION MENU 6.11 LOAD FACTORY DEFAULTS 6.12 VIEW PUMP INFORMATION This feature will return the pump parameters to Display Overview: factory defaults and return pump to default state see Sec. 4.0 changes. Display Overview: Confirmation Box 1.
Page 32
We are a proud member of Accudyne Industries, a leading global provider of precision-engineered, process-critical, and technologically advanced flow control systems and industrial compressors. Delivering consistently high levels of performance, we enable customers in the most important industries and harshest environments around the world to accomplish their missions.