Monitoring The Value Of The Daily Totalizer; Details Of The Information Menu - Burkert 8025 Series Operating Instructions Manual

Universal flow transmitter
Hide thumbs Also See for 8025 Series:
Table of Contents

Advertisement

Available languages

Available languages

8.7.5

monitoring the value of the daily totalizer

The parameter "VOLUME-W." makes it possible to monitor the value of the daily totalizer. When the set value is
reached, a warning message is generated by the device.
To deactivate the monitoring of the totalizer, set "VOLUME-W." to zero.
wARNiNG
END
Figure 54:
Diagram of the "VOLUME-W." parameter of the Test menu
When the warning message "WARN. VOL." is sent out, reset the totalizer: see chap. "8.5" or "8.6.15".
If you do not want to adjust another parameter, confirm the "END" parameter to save the settings or not and
go back to the Process level.
8.8

Details of the Information menu

• This menu is available when the device status LED is orange or red.
• For the meaning of a message, go to chap. "9.3.2" and "9.3.3".
To access the Information menu, press the
In this menu read the fault and warning messages generated by the device.
Figure 55:
Diagram of the Information menu
58
VOLUME-w.
= 0000000
Enter the volume of the daily totalizer for which a warning message
is generated by the device.
Confirm.
REtURN
MESSAGE 1
0......9
MESSAGE 2
MESSAGE N
0......9
ENTER
END
English
key for at least 2 s, in the Process level.
Process level
Type 8025 UNIVERSAL
Operatingandcommissioning

Advertisement

Chapters

Table of Contents
loading

Table of Contents