Mechanical properties

3.1

Cooling

The 1FK2 is a non-ventilated motor.
To ensure sufficient heat dissipation when installed, the motor requires a minimum clearance
of 100 mm from adjacent components on three sides.
● Maintain theses clearances irrespective of the following mounting variants.
Non-thermally insulated mounting
Some of the motor power loss is dissipated through the flange when the motor is connected
to the mounting surface.
● Observe the following mounting conditions for the specified motor data:
The data in the table refers to an ambient temperature of 40 °C and an installation altitude up
to 1000 m above sea level.
If the environmental conditions are different, derating may be required. You can find
information on this in the section "Derating factors (Page 26)".
For larger mounting surfaces, the heat dissipation conditions improve.
Thermally insulated mounting without additional mounted components
For self-cooled motors, you must reduce the S1-characteristic curve as follows:
Reduce the motor static torque by a range of 20% to 30%.
Reduce the torque at 3000 rpm by a range of 40% to 50%.
1FK2 synchronous motors for SINAMICS S120
Configuration Manual, 06/2019, A5E46927724B AB
Shaft height
1FK2❑03
1FK2❑04
1FK2❑05
1FK2❑06
1FK2❑08
1FK2❑10
Steel plate, width x height x thickness (in mm)
250 x 250 x 6
300 x 300 x 12
450 x 370 x 30