Routing Cables In A Damp Environment - Siemens SIMOTICS S-1FK2 Series Configuration Manual

Synchronous motors for sinamics s120
Hide thumbs Also See for SIMOTICS S-1FK2 Series:
Table of Contents

Advertisement

Electrical connection
8.3 System integration
Releasing a SPEED-CONNECT connection
Procedure
1. Turn the union nut of the SPEED-CONNECT connector in the direction of "open" to the
end stop. The triangles on the top of the connectors must be opposite one another.
2. Withdraw the connector.
Note
Pull out the connector at the connector itself, and do not pull on the cable.
You have disconnected the SPEED-CONNECT connection.
8.3.4.3

Routing cables in a damp environment

Note
If the motor is mounted in a humid environment, the power and signal cables must be routed
as shown in the following figure.
Figure 8-2
110
Routing cables in a damp environment
1FK2 synchronous motors for SINAMICS S120
Configuration Manual, 06/2019, A5E46927724B AB

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents