Long-term storage
Note
Storage time up to two years
The storage time affects the properties of the roller bearing grease.
• Store the motor for up to two years at -15° C to 55° C.
If you intend to place the motor in storage for longer than six months, you must ensure that
the storage area satisfies the following conditions.
Table 7- 1
Climatic ambient conditions
Highest relative humidity
Mechanical ambient conditions
Protection against chemical substances
Biological ambient conditions
Duration
Check the correct state of the motor every six months.
● Check the motor for any damage.
● Perform any necessary maintenance work.
● Check the state of the dehydrating agent and replace when necessary.
● Record the preservation work so that all preservation coating can be removed prior to the
commissioning.
Condensation
The following ambient conditions encourage the formation of condensation:
● Large fluctuations of the ambient temperature
● Direct sunshine
● High air humidity during storage.
Avoid these ambient conditions.
Use a dehydrating agent in the packaging.
1FK2 synchronous motors for SINAMICS S120
Configuration Manual, 06/2019, A5E46927724B AB
Environmental conditions for long-term storage in the product packaging according to
Class 1K3 to EN 60721-3-1 - with the exception of influencing environmental variables
"Air temperature", "Highest relative humidity" and "Condensation"
- 15 °C ... + 55 °C
< 60%, condensation not permissible
vibration-free storage room v
Protected in acc. with Class 1C2
Suitable in acc. with Class 1B2
• Six months for the conditions listed above.
• Special preservation measures are
required for storage times of 6 months up
to maximum of two years.
Preparation for use
7.2 Storage
< 0.2 mm/s