Timing begins each time a body enters the first photogate (input 1) and
ends when leaving the second photogate (input 2). MultiLogPRO then
displays the elapsed time between entering the gates and the body's
average velocity and acceleration
Use the arrow buttons to scroll between the time, speed and
acceleration results
Press Escape
Press Escape
Select Sensors Manually
You must be in 8 input mode to be able to select the sensors manually (see page 7).
In the Main Menu screen, use the arrow buttons to select the setup
menu icon
Press the Enter button
Use the Forward
sensor in input 1 and then press the Enter button
indicator will move to the second input.
Repeat this procedure with all the sensors you plugged in.
Fourier Systems Ltd.
16 Hamelacha St., POB 11681, Rosh Ha'ayin 48091,
Tel: +972-3-901-4849, Fax: +972-3-901-4999
www.FourierEdu.com
to return to the timing menu
a second time to return to the main menu
.
In–1: Empty
In–2: Empty
In–3: Empty
In–4: Empty
RATE = 10/s
SAMPLES = 500
DISPLAY = numeric
and Backward
to enter the setup menu:
arrows to select the
EXPERIENCE SCIENCE!
. The arrow