Strobe safety
• Flashing light, particularly at 5 - 30 Hz, may cause seizures in persons with
photosensitive epilepsy. Do not use strobe effects for extended periods.
• Comply with local regulations on the use of strobe lighting and notify the public in
advance with highly visible warning signs when strobe effects are used.
• If a seizure occurs, stop using strobe effects. Seek professional medical help. Note the
time that the seizure starts and finishes. Call emergency medical help urgently if the
seizure lasts more than five minutes, if it is the person's first seizure, or if the person is
injured. While waiting for help to arrive, consider the following general advice for
caring for a person who is having a seizure: Protect the affected person from injuring
themselves on hard or sharp objects. If necessary, move the person to a safe place.
Lay them on their side with their head supported to prevent it from hitting the floor.
Loosen any tight clothing around their neck. Do not use force to hold the person or
restrict their movements. Do not put anything in their mouth, including your fingers.
Installation safety and protection from personal injury
• Installation must be performed by qualified personnel only and carried out in
accordance with applicable regulations such as DIN VDE 0711-217.
• Restrict access below the work area and work from a stable platform whenever
installing, servicing or moving the luminaire.
• Mount the luminaire only on EUTRAC 3 lighting track that is correctly and safely
installed and rated for the weight of all the devices that will be installed on it.
• When installing a luminaire, support its weight until you have closed both of the two
mechanical fasteners at each side of the luminaire to lock the fasteners into the
lighting track. Do not allow the luminaire to hang from only one mechanical fastener.
• Allow a minimum center-to-center distance of 1000 mm / 40 in. between luminaires
on the lighting track. Do not install luminaires at less than this distance from each other
or you may overload the track and cause a safety hazard.
• Secure the luminaire against falling if the primary trackmount adapter fails by
equipping it with a safety cable as directed in this manual. The safety cable must be
approved for the weight of the luminaire and fastened to a secure anchoring point in
a fixed structure. If no fixed structure is available, secure the luminaire using the safety
cable and retaining collar supplied with the luminaire (or identical replacement items
supplied by GLP) as directed in this manual.
impression® FR1 TM User Manual
7