Advertisement

Quick Links

Software version V. 20

Advertisement

Table of Contents
loading

Summary of Contents for GLP impression FR1O BAR

  • Page 1 Software version V. 20...
  • Page 2 This manual covers fixture software version V. 20 © 2019 German Light Products GmbH. All rights reserved. The marks ‘GLP’ and ‘German Light Products’ are trademarks registered as the property of German Light Products GmbH in Germany, in the United States of America and in other countries.
  • Page 3: Table Of Contents

    7. Connecting to DMX data .............. 18 8. Starting and stopping operation........... 19 Transportation and storage ............19 9. Service ..................... 20 Removing the front glass ............20 Cleaning ..................20 GLP Service and Support ............21 10. Technical specifications .............. 22 11. Dimensions ..................24...
  • Page 4: Safety

    Warning! Risk of eye injury. General safety information Read this manual carefully before installing, using or servicing the GLP impression FR 10 Bar lighting fixture. If you have any doubts or questions about how to use the fixture safely, contact your GLP®...
  • Page 5: Electrical Safety

    • Check the GLP website at www.glp.de and make sure that you have the latest version of this manual. Check the fixture software version indicated on page 2 of this manual and then use the fixture’s control panel to check the version installed in the...
  • Page 6: Fire Safety And Protection From Burns

    • Do not place any optical components other than impression FR 10 Bar accessories from GLP onto the front of the fixture. • Do not stick filters, masks or other materials onto the fixture. Do not block the light output in any way.
  • Page 7: Eye Safety

    German Light Products® clean and unobstructed at all times in order to prevent a fire hazard and damage to the fixture. • The fixture’s optical components can focus the sun’s rays, creating a risk of fire and damage. Do not expose the front of the fixture to sunlight or any other intense light source, even from an angle.
  • Page 8: Installation Safety And Protection From Personal Injury

    Do not attempt to use a fixture that is obviously damaged. • Do not modify the fixture in any way not described in its user documentation. • Install genuine GLP parts only. impression FR10 Bar Quick Start and Safety Manual Rev. A...
  • Page 9: Avoiding Damage To The Fixture

    German Light Products® 2. Avoiding damage to the fixture Important! Follow the directions in this section carefully, or the fixture may suffer damage that is not covered by the product warranty. General precautions Do not drop the fixture or expose it to mechanical stress. Protect the LCD display and control panel from shocks, or they may suffer damage that is not covered by the product warranty.
  • Page 10: Avoiding Damage From Dust And Airborne Particles

    Do not operate the fixture in ambient temperatures above 45° C / 113° F or below 5° C / 41° F. Allow free airflow around the fixture. Avoiding damage from dust and airborne particles • Carry out regular visual inspections of the fixture to make sure that there is no accumulation of dirt, especially on the front of the fixture and around air vents.
  • Page 11: 10 Bar Overview

    German Light Products® 3. FR 10 Bar overview Figure 2. FR 10 Bar overview A – Head B – Pixel zoom lens C – Alignment pins button D – DMX IN (5-pin XLR) E – AC mains power IN (Neutrik powerCON TRUE1) F –...
  • Page 12: Features

    4. Features The impression FR 10 Bar from GLP can be used in dry locations in permanent and temporary installations. Fixtures can be placed on or fastened to a level surface, or they can be suspended from a suitable structure as directed in this manual.
  • Page 13: Installation

    German Light Products® 5. Installation Warning! Read ‘Safety’ starting on page 4 for important safety information that you must understand before you install or operate the fixture. Install FR 10 Bar fixtures only as described in this chapter, or you may create an installation that is unsafe.
  • Page 14: End-To-End Alignment

    Loop the cable around a secure anchoring point such as a truss chord or fixed structure so that it will catch the fixture if a rigging clamp fails. Take up as much slack as possible in the safety cable (by looping it more than once around the truss chord, for example).
  • Page 15: Installing On A Rigging Truss Or Similar Structure

    Installing on a rigging truss or similar structure You can suspend an FR 10 Bar fixture from a rigging truss or pipe using the brackets that are supplied with the fixture and rigging clamps that are available from GLP as optional accessories.
  • Page 16: Ac Mains Power

    6. AC mains power Warning! Read ‘Safety’ starting on page 4 for important safety information that you must understand before you install or operate the fixture. Check that all cables and connectors are suitable for the installation environment and application (see recommendations in ‘Avoiding damage to the fixture’...
  • Page 17: Installing Power Connectors

    German Light Products® Installing power connectors If you intend to draw power from convenience receptacles / consumer mains power sockets, it is possible to install a suitable cord cap / power plug on the supplied power cord / input cable. If you do this, check that the cord cap / plug is rated minimum 250 V, 16 A, that it has a connection to ground / earth and that it has an integral cable grip.
  • Page 18: Connecting To Dmx Data

    Ethernet cables for the data link if connecting to the Ethernet ports. The EtherCON sockets use fail-safe technology that allows data through even if the fixture is powered off. If you would like advice with planning and installing a DMX link, your GLP supplier will be happy to provide assistance. impression...
  • Page 19: Starting And Stopping Operation

    German Light Products® 8. Starting and stopping operation Warning! Before you apply power to the fixture or operate it after a blackout, make sure that nobody is looking directly into the front of the fixture and that there is sufficient clearance for the head to tilt safely. The FR 10 Bar’s TRUE1 mains power input connector supports hot-plugging, and connecting and disconnecting a live power cable is an option, especially if you need to shut down power urgently, but it is still good practice to shut down power to the AC...
  • Page 20: Service

    It is possible to remove the front cover for cleaning or to replace it with one of the custom front covers available from GLP. To remove the front cover: Place the fixture on a work surface with the head upright.
  • Page 21: Glp Service And Support

    German Light Products® GLP Service and Support Contact information for the nearest GLP Service and Support is available online at www.glp.de/en/service, by email at info@glp.de, or by telephone at the following numbers: • GLP Germany: +49 (7248) 927 19-55 • GLP N. America: +1 818 767-8899 •...
  • Page 22: Technical Specifications

    10. Technical specifications Optics Total luminous output: 5860 lumens (wide), 4374 lumens (narrow) Light source: 10 x 60 W OSRAM Ostar RGBW LEDs Lifetime: 50 000 hrs. approx. to > 70% luminous output Zoom ratio: 1:7 Minimum zoom angle: 3.7° half-peak (50%), 7° field angle (10%), 8° cutoff angle (3%) Maximum zoom angle: 25°...
  • Page 23 German Light Products® Electrical AC mains power: 100-240 V nominal, 50/60 Hz Power supply unit: Auto-ranging electronic switch mode Maximum power consumption, all LEDs at 100% output: 800 W Idle power consumption, all LEDs at 0% output: 80 W Primary fuse: T 12 A, 250 V, 6x32 mm Maximum permitted number of fixtures daisy-chained to power 2 x FR 10 Bar total @ 100-120 V, 60 Hz 4 x FR 10 Bar total @ 200-240 V, 50 Hz...
  • Page 24: Dimensions

    11. Dimensions FR 10 Bar All dimensions are in millimeters 1000 Folding brackets impression FR10 Bar Quick Start and Safety Manual Rev. A...