GLP impression FR1 TM User Manual page 16

Trackmount
Hide thumbs Also See for impression FR1 TM:
Table of Contents

Advertisement

www.glp.de
See Figure 5. At the end of the track
adapter next to the wireless linking
button, use the lever (arrowed) to
close the main mechanical fastener.
This will fix one side of the luminaire
into the track and make the
connection to the Neutral line inside
the track. You must continue to
support the weight of the luminaire
until you have closed the other
mechanical fastener – do not allow
the luminaire to hang from one
fastener only.
At the antenna end of the track adapter, close the second fastener to fix the other
side of the luminaire into the track. Make the connection to one of the three power
phases by turning and/or pulling the knob on the fastener as follows:
• Turn clockwise = Phase 1
• Turn counter-clockwise =
Phase 2
• Pull and turn counter-
clockwise = Phase 3
• Pull and turn clockwise =
Neutral
See Figure 6. Note the position
of the safety cable
attachment point (arrowed) in
the luminaire's baseplate.
Install a safety cable as
directed below.
Warning! Secure the luminaire with a safety cable using one of the two
options described in the following section. Do not leave an FR1 TM
luminaire suspended in lighting track unless it is secured with a safety cable.
Option 1: Anchoring to a building or rigging structure
Provide a secure anchoring point such as a building member, eyebolt screwed into
a secure surface or rigging structure.
Obtain a safety cable that is approved by TÜV, UL or a similar organization as a
safety attachment for the weight of the luminaire. Fasten the safety cable to the
16
Figure 5. Main mechanical fastener
Attachment point
Figure 6. Safety cable
attachment point