GLP impression FR1 TM User Manual page 17

Trackmount
Hide thumbs Also See for impression FR1 TM:
Table of Contents

Advertisement

German Light Products®
anchoring point and to the safety cable attachment point in the luminaire's
baseplate so that it will hold the luminaire if the rigging clamp fails. Take up as
much slack as possible in the safety cable (by looping it more than once around
the rigging structure, for example).
Check that the luminaire will be held securely by the safety cable if the primary
attachment method fails.
Make sure that the head will not collide with another luminaire or any other object
when it tilts and rotates.
If you are going to install another luminaire on the same lighting track, allow a 1000
mm / 40 in. center-to-center distance between luminaires, or you may overload the
lighting track and cause a safety hazard.
Option 2: Anchoring to the lighting track
Check that power to the lighting track is still locked out.
Figure 7. Installing a retaining collar and safety cable
See Figure 7. Note the flanges (arrowed) on the sides of the retaining collar that is
supplied with the luminaire.
Pass the flanges into the lighting track immediately next to the luminaire and turn
the retaining collar fully clockwise so that the flanges extend fully into the track.
Screw the M8 eyebolt on the end of the safety cable that is supplied with the
luminaire firmly into the retaining collar. Check that the eyebolt is now held securely
in the lighting track.
impression® FR1 TM User Manual
17

Advertisement

Table of Contents
loading

Table of Contents