Quick Start Guide
NOTICE
This guide provides basic guidelines for the installation of the Rosemount 9295 Primary Element. For
comprehensive instructions on configuration, diagnostics, maintenance, service or troubleshooting, refer to
the Rosemount 9295 Primary Element Reference Manual and appropriate transmitter reference manuals. The
manual and this guide are also available electronically on Emerson.com/Rosemount.
If the Rosemount 9295 Primary Element was ordered assembled to a Rosemount Pressure Transmitter,
Manifold or RTD, refer to the following Quick Start Guides for information on configuration and hazardous
locations certifications:
Rosemount 3051S Quick Start Guide
Rosemount 3051SMV Quick Start Guide
Rosemount 3051 Quick Start Guide
Rosemount 2051 Quick Start Guide
Rosemount 214C (RTD) Quick Start Guide
Hazardous Area Approvals: This assembly is assembled from certified pieces of equipment. The overall
assembly is subject to inspection by the authority having jurisdiction over the installation.
If the meter was ordered with a wireless transmitter, the battery will be shipped separately due to freight
carrier regulations.
Process leaks may cause harm or result in death.
To avoid process leaks, only use gaskets and O-rings designed for the corresponding flange to seal process
connections.
Transmitter electronics maintenance should not be conducted on energized equipment in a hazardous
atmosphere.
Failure to comply with the requirements for intrinsic safety in a hazardous atmosphere could result in an
explosion.
If the process fluid is hazardous, the procedure outlined here should be modified as required.
Failure to do so could result in serious injury to personnel or death.
If the line is pressurized, always open valves slowly.
Failure to do so could result in serious injury to personnel or death.
During installation, never lift the meter by the transmitter, RTD or impulse lines/valves.
Doing so may result in meter damage and serious injury.
Contents
Before you begin . . . . . . . . . . . . . . . . . . . . . . . . . 3
Locate the installation point . . . . . . . . . . . . . . . 4
Orient the primary element . . . . . . . . . . . . . . . . 7
Install the primary element . . . . . . . . . . . . . . . 11
2
Trim the transmitter . . . . . . . . . . . . . . . . . . . . . 14
Additional information . . . . . . . . . . . . . . . . . . . 15
Declaration of Conformity . . . . . . . . . . . . . . . . 16