Garnet SeeLeveL Special 809-DM User Manual page 32

Truck multi tank dispensing system
Table of Contents

Advertisement

Wire Color (9 pin pigtail)
RED
BLACK
BLACK
YELLOW/WHITE
PURPLE/WHITE
PURPLE
BROWN
GREEN/WHITE
GREY/WHITE
12. Contact Garnet for wiring diagrams and external connection
information. To program the alarms see the alarm
programming section.
13. Program the gauge as directed in the programming section.
To determine the bottom reading of the gauge, measure from
the bottom of the tank to the middle of the straight vertical
part of the float when the float is resting on the anchor. Do
NOT set the gauge to read "0" at the bottom since this will not
result in a correct reading when the float is actually floating on
the product. In addition, if the gauge ever goes below "0" due
to tank expansion, it will read some nonsensical value since
this region has not been programmed.
14. Fasten on the front panel with the four Phillips screws in the
corners. Do not over tighten the screws, the front panel may
crack. Verify the correct orientation of the front panel to
ensure the gasket is correctly seated.
15. Verify gauge operation by lifting each float. Record the unit
number, calibration units, minimum and maximum readout
values, and any alarm points programmed in the IMPORTANT
OPERATOR INFORMATION area on the front page of the
owner's manual. The truck operator must be given the
owner's manual upon delivery with all front page data
filled in.
Page 32
Function
+12V power input (required)
Ground (required)
Ground (additional if needed)
Serial Port Receive
Serial Port Transmit
PTO Input (required for serial data
transmission and alarm operation)
Remote Input 1
Remote Input 2
Remote Input 3
809-DM Manual