'x' requests the delay in seconds after the PTO has engaged before
the level is read and transmitted.
x<CR>
x,0<CR>
PTO status request
'p' requests the PTO status from the 809-DM where 'E' is PTO
engaged and 'D' is PTO disengaged.
Engaged
p<CR>
p,E<CR>
Scan all compartments
's' request a scan of all configured compartments, including
the remote inputs if enabled. The 809-DM sends out a comma
separated list of values corresponding to the PTO status followed
by the number of channels being monitored.
s<CR>
s,D,11.16,79.00, 0.00, 0.00, 0.00, 0.00<CR>
s<CR>
s,E,11.16,79.00<CR>
Scan a specific compartment
's1' to 's6' request a scan of a specific compartment. The 809-DM
sends out a value corresponding to the requested compartment.
's7' to 's9' transmits the remote tank levels.
s1<CR>
s1,11.16<CR>
s4<CR>
s4, 0.00<CR>
Request Number of Channels
'c' reads the number of channels being monitored and displayed
on the LCD screen. This normally corresponds to the number of
connected SEELEVEL™ gauges (see above).
c<CR>
c,1<CR>
Set Viewing/Working Tank and Dispensing Amount
The 809-DM can be remotely programmed to dispense set
amounts out of specific tanks. The format is as follows: f=tank
number: number of units to dispense alarm, number of units must
be 3 digits. Number of units is number of gauge increments (eg
1/3" or 1/6").
Page 22
f=3:006<CR>
f,3:006<CR>
x<CR>
x,10<CR>
Disengaged
p<CR>
p,D<CR>
s2<CR>
s2,79.00<CR>
s5<CR>
s5, 0.00<CR>
c<CR>
c,6<CR>
s3<CR>
s3, 0.00<CR>
s6<CR>
s6, 0.00<CR>
809-DM Manual