9. Cut the fiber ends square with a sharp knife and insert
10. Inspect the head cap for casting flash, lightly sand or
11. At the display, connect the wiring according to the
809-DM Manual
the end of the Synflex near to the display box and feed
the fiber optic cable through the hose, leaving about 12
inches extra at the head end. Route the fiber into the box
through the hole that was drilled.
the fiber into the connectors at each end and tighten the
connector lock nuts. Make sure that the fiber is loosely
coiled inside the enclosure and is not pulled tight or bent
sharp. The display should change from reading "no L" to
some inch value as soon as the fiber is connected. If not,
check that the fiber ends are clean and cut square, and
that the fiber is fully inserted into the connectors at each
end.
scrape off any casting protrusions. Make sure that there
is grease on the rubber O-ring and snap on the head cap.
following table. It is only necessary to connect the wires
that are required for the application. The +12V power
and ground wires must be connected for the gauge to
function. All other wires are either optional or are for
optional accessories.
Wire Color (6 pin pigtail) Function
GREEN/YELLOW
WHITE
GREY
YELLOW
ORANGE
BLUE
Dispense Alarm Common
Dispense Alarm Normally Open
Overfill shutdown Alarm
Common
Overfill shutdown Alarm
Normally Open
Auxiliary Alarm (for future use)
Overfill warning Alarm