Garnet SeeLeveL Special 809-DM User Manual page 21

Truck multi tank dispensing system
Table of Contents

Advertisement

3. Transmit delay upon PTO disengagement.
4. Transmit delay upon PTO engagement.
'u=1' turns the PTO pullup on, 'u=0" turns the PTO pullup off.
u=1<CR>
u,1<CR>
'e=1' means the PTO is engaged when the signal is high (+12V),
'e=0' means the PTO is engaged when the signal is low (ground).
e=1<CR>
e,1<CR>
'w=0' to 'w=99' sets the delay in seconds after the PTO has
disengaged before the level is read and transmitted. Numbers
larger than 99 will be ignored. This gives time for the liquid
agitation due to loading to settle. During this delay new gauge
values will be continue to be read. Once the delay expires, new
gauge values will be ignored.
w=0<CR>
w,0<CR>
'x=0' to 'x=99' sets the delay in seconds after the PTO has engaged
before the level is read and transmitted. Numbers larger than
99 will be ignored. This gives time for the liquid agitation due
to the trucking moving to settle. If the delay is set to 0, then
the stored values obtained when the PTO was disengaged will be
transmitted, since there will not have been any time to read the
new values from the gauges.
x=0<CR>
x,0<CR>
Request PTO configuration
'u' requests the PTO configuration for the pullup.
Pullup turned on
u<CR>
u,1<CR>
'e' requests the PTO configuration for the engagement polarity.
Engaged when high
e<CR>
e,1<CR>
'w' requests the delay in seconds after the PTO has disengaged
before the level is read and transmitted.
w<CR>
w,0<CR>
809-DM Manual
u=0<CR>
u,0<CR>
e=0<CR>
e,0<CR>
w=60<CR>
w,60<CR>
x=60<CR>
x,60<CR>
Pullup turned off
u<CR>
u,0<CR>
Engaged when low
e<CR>
e,0<CR>
w<CR>
w,60<CR>
Page 21