This example would set the display to tank 3, and set the dispense
alarm set point to 6 increments. With a 1/6" increment, the
dispense alarm would activate after a change of 1".
Any error in formatting or number of compartments returns f,?
Setting the dispense units to zero clears the dispense alarm.
Set Update Interval (0=no automatic updates)
The 809-DM can be configured to automatically send updates
on a timed interval. The update interval is specified in seconds,
the value must be between 0 and 99,999 seconds. Values larger
than 99,999 will be ignored. Within approximately one second
of setting the interval, the first interval transmission will be done.
By setting the update interval to 0, automatic updates are turned
off.
Set Transmit Interval Options
The 809-DM can be configured to send or not send interval
updates during the time that the PTO is disengaged. Updates are
always sent during the time that the PTO is engaged.
Request Transmit Interval Options
Interval Update
When an auto update interval has been defined, the 809-DM
sends out a comma separated list of values corresponding to the
PTO status followed by the number of channels being monitored
on the defined interval, followed by the time and date. The interval
is specified in seconds.
i,E,11.16,79.00, 0.00, 0.00, 0.00, 0.00,12:48:16A Mar 23 2008<CR>
Dispensing Status Request
'b' requests the 809-DM dispensing status.
Dispensing
b<CR>
b,1<CR>
809-DM Manual
i=60<CR>
i,60<CR>
i=0<CR>
i,0<CR>
Do send
o=1<CR>
o,1<CR>
Do send
o<CR>
o,1<CR>
i=7200<CR>
i,7200<CR>
Do not send
o=0<CR>
o,0<CR>
Do not send
o<CR>
o,0<CR>
Not dispensing
b<CR>
b,0<CR>
Page 23