5. Make up an anchor by cutting a 4" X 16" piece of 1/4" thick
material. Bend each end down at 90 degrees (see the diagram
below), so the resulting flat piece is about 4" X 10" inches with
3" sides. Drill a hole to insert a 2"ID schedule 40 pipe in the
center of the plate, weld tube to plate. Insert the bar into the
tank and slide the anchor assembly over the sensor bar with
the "U" facing down. Align the sensor bar vertically and weld
the anchor in place to the bottom of the tank. Pull the sensor
bar up a bit and slide the float (cone side up) over the bar.
Lower the bar back into the anchor.
6. Tighten the base of the compression fitting into the coupler.
Lift the bar 1" off the bottom of the tank, and tighten down
the compression fitting nut. Raise and lower the float a few
inches to set the bottom reading.
7. Pick a spot for the display. Make sure that the display is
visible during normal operation of dispensing from the tanks
and filling of the tanks. Make up a bracket to hold the box
in position and mount the box, but leave the front panel off.
The front panel is held on by the four small Phillips screws in
the corners.
8. Route 1/4" Nylon air brake hose (Synflex) from each sender
head to the display and fasten with a brass insert and
compression fitting at the head end. Drill holes in the side of
the box (make sure the front panel is out) for the fiber and the
wiring. At the lowest point in the air line insert a T fitting with
approximately two feet of Synflex hanging down to provide
a drain for any water than may get into the system. Locate
Page 30