Set number of Remote Tanks
'h=' sets the number of remote inputs to be scanned. 'h=0' is no
water tank scanning, 'h=1' one remote tank, 'h=2' two remotes,
'h=3' three remotes.
One water tank input being scanned
h=1<CR>
h,1<CR>
Request Alarm Status
'a' requests the current alarm status. The reply is 'a,A4-A3-A2-A1'
where '0' means that an alarm is open, and '1' means an alarm is
closed. 'Invalid' is sent if any compartment is in error.
a<CR>
a,0-0-1-1<CR>
Request Time
't' requests the current time and date.
t<CR>
t,12:48:16AM Mar 23 2008<CR>
Set Time
't=' set the time. The format is hour, minute, second, A or P, each
represented by 2 digits and separated by a colon. The hour may
or may not have the leading zero, but the minutes and seconds
must have the leading zero.
t=04:46:09P<CR>
t, 4:46:09P Mar 04 2008<CR> t, 12:06:09A Mar 04 2008<CR>
Set Date
'd=' set the date. The format is month, date, year, each represented
by 2 digits and separated by a colon. The month may or may
not have the leading zero, but the date and year must have the
leading zero.
d=03:04:08<CR>
t,12:48:16A Mar 4 2008<CR>
Version Request
'v' requests the current 809-DM software version.
v<CR>
v,SeeLeveL 809DM,HW E,SW 5.18<CR>
Newer versions of gauge software may report more
information.
Page 24
t=12:06:09A<CR>
d=3:04:08<CR>
t,12:48:16A Mar 4 2008<CR>
809-DM Manual

Hide quick links: