Omron CJ-Series Operation Manual page 78

Built-in i/o. cpu units
Hide thumbs Also See for CJ-Series:
Table of Contents

Advertisement

PLC Setup Settings
Pulse Output 0 Origin Search High Speed
Programming
Settings
Console setting
address
Word
Bit
260
00 to 15 00000001 to
000186A0 hex
261
00 to 15
(See note.)
Pulse Output 0 Origin Search Proximity Speed
Programming
Settings
Console setting
address
Word
Bit
262
00 to 15 00000001 to
000186A0 hex
263
00 to 15
(See note.)
Pulse Output 0 Search Compensation Value (Origin Compensation)
Programming
Settings
Console setting
address
Word
Bit
264
00 to 15 80000000 to
7FFFFFFF hex
265
00 to 15
(See note.)
Pulse Output 0 Origin Search Acceleration Rate
Programming
Settings
Console setting
address
Word
Bit
266
00 to 15 0001 to 07D0 hex
(See note.)
Pulse Output 0 Origin Search Deceleration Rate
Programming
Settings
Console setting
address
Word
Bit
267
00 to 15 0001 to 07D0 hex
(See note.)
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
00000000
Specifies the high speed setting (1 to
hex
100,000 pps) for pulse output 0 origin
search operation.
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
00000000
Specifies the proximity speed setting
He
(1 to 100,000 pps) for pulse output 0
origin search operation.
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
---
Sets the pulse output 0 origin com-
pensation (−2,147,483,648 to
2,147,483,647).
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
---
Sets the origin search acceleration
rate for pulse output 0 (1 to 2,000
pulses/4 ms).
Note When the CX-Programmer is being used to make the setting, the setting is
input in decimal.
Default
---
Sets the origin search deceleration
rate for pulse output 0 (1 to 2,000
pulses/4 ms).
Function
Area flags/
---
Function
Area flags/
Function
Area flags/
---
Function
Area flags/
---
Function
Area flags/
---
Section 4-2
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
Related
Time when
Auxiliary
setting is read
by CPU Unit
bits
When operation
starts
59

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cj1m-cpu22Cj1m-cpu23

Table of Contents