System diagnostics

10.2 Diagnostic functions

Flashing of
red LED on
reader
30
-
Note
Error message when memory area is protected
For transponders with a locked or protected memory area, different error messages can
occur following a write command depending on the data carrier type, e.g. MDS D1xx (NXP),
D3xx (Infineon), D4xx (Fujitsu): Error 01, 0C
10.2
Diagnostic functions
Further information on RFID diagnostic options can be found in Function Manual FB 45
(http://support.automation.siemens.com/WW/view/en/21738808).
10.2.1

Reader diagnostics with SLG STATUS

The SLG STATUS command can be used to scan the status and diagnostics data of the
reader.
SLG STATUS (mode 01), corresponds to UDT 110
Name
hardware
hardware_version
loader_version
firmware
260
Error code
Description
(hexa-
decimal)
1E
Incorrect number of characters in frame
1F
Running command cancelled by "RESET" command
Type
Possible values
char
(31 to 38 hex)
31 hex
32 hex
33 hex
34 hex
3A hex
word
0 to FF hex
0 to FF hex
word
0 to FF hex
0 to FF hex
char
0 to FF hex
Comment
Type of hardware
= RF260R
= RF210/220R
= RF240R
= RF250R
= RF290R
HW version (reserved)
= Version (high byte)
= Version (low byte)
Bootstrap loader version: e.g. 3130 (=version
1.0)
= Version (high byte)
= Version (low byte)
FW version : 33 (ASCII : 3 = RF2x0R)
System Manual, 09/2013, J31069-D0227-U001-A8-7618
SIMATIC RF200