Reset_Rf300 - Siemens SIMATIC Ident Function Manual

Rfid systems. ident profile, add-on instruction for rockwell systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

4.5.5.4

Reset_RF300

Figure 4-25
Table 4- 39
Parameter
TAG_CONTROL
TAG_TYPE
RF_POWER
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
Instruction "Reset_RF300"
Explanation for the instruction "preset_RF300"
Data type
SINT
SINT
SINT
4.5 Programming add-on instructions
Default values
Description
1
Presence check
0 = Off
1 = on
4 = presence (antenna is off. The
antenna is turned on only when a
Read or Write command is sent.)
0
Transponder type:
1 = every ISO transponder
0 = RF300 transponder
0
Output power; only relevant for
RF380R
RF power from 0.5 W to 2 W in incre-
ments of 0.25 W (range of values:
0x02 ... 0x08).
Default value: 0x00 ≙ 1.25 W.
This setting is not necessary with the
RF380R readers of the 2nd generation
(6GT2801-3BAx0) because the power
limits are optimized automatically
depending on the reader-transponder
distance.
Configuring the instructions
55