Siemens SIMATIC Ident Function Manual page 69

Rfid systems. ident profile, add-on instruction for rockwell systems
Hide thumbs Also See for SIMATIC Ident:
Table of Contents

Advertisement

Parameter
EXT_UHF
LEN_ID
MEM_BANK
PSWD
EDIT_BLACKLIST_MODE
INVENTORY_DURATION
INVENTORY_DUR_UNIT
LOCK-TAG-
BANK_ACTION
LOCK-TAG-BANK_MASK
Ident profile, Add-on instruction for Rockwell systems
Function Manual, 01/2019, C79000-G8976-C410-03
Data type
Default val-
ue
STRUCT
--
SINT
0
SINT
3
DINT
0
SINT
0
DINT
0
DINT
0
DINT
0
DINT
0
4.6 Programming the Ident profile
Description
Structure for additional parameters (RF680R/RF685R
only)
Length of the valid data in the "EPCID_UID" field.
Memory bank on the transponder
0x00 = RESERVED
0x01 = EPC
0x02 = TID
0x03 = USER
Password for transponder access
0x00 ≙ no password
Mode
0x00 = add EPC-ID
0x01 = add all "Observed" transponders
0x02 = delete EPC-ID
0x03 = delete all
Duration
Period of time or number of inventories or number of
"Observed" events
Example:
0x00 ≙ no inventory
0x01 ≙ one inventory
Unit for "DURATION"
0x00 = time [ms]
0x01 = inventories
0x02 = number of "Observed" events
Lock-Action (see "EPC Specification")
Lock-Mask (see "EPC Specification")
Configuring the instructions