Screen
9 : Transmission
parameters
The upper display shows "AO" the word
indicates the transmitter output parameters.
The first line indicates unidirectional /
bidirectional: 0 for unidirectional, 1 for
bidirectional;
The second line indicates the type of
association, as described in the ninth parameter
setting screen;
The third line indicates the electric parameters
sent to the output range of the association.
Screen 10:Time of back-light lighting
The upper display shows "Ld-T" word represents the
time of back-light lighting.
As shown in fig. 3-2-33: the time of back-light lighting is
30 minutes, that is, within 30 minutes of no buttons are
pressed, the back-light lighting automatically turns off; When
it is zero, indicating that the back-light lighting is on.
the time of back-light lighting
Note:
Screen 11 : Statistical interval of the energy max/min
value
The upper display shows "S - T" word indicates the statistical
interval of the energy max/min value.
As shown in fig. 3-2-34:
energy max/min value is 1440 minutes.
Note: The statistical interval of the energy max/min default value is 10
minutes.
IM300 Intelligent Power Monitoring Instrument
output
default is 5 minutes.
the time of statistical interval of
23
Fig 3-2-32 Transmission output settings page
fig. 3-2-33 Backlight lighting time
Fig 3-2-34 Statistical interval of the
energy max/min value