On MR Configurator2
Clicking "Return to initial value" in the one-touch tuning window of MR Configurator2 enables to return the servo parameter to
the initial value.
Clicking "Return to value before adjustment" in the one-touch tuning window of MR Configurator2 enables to return the servo
parameter to the value before clicking the start button. The setting value of the returned servo parameter is stored in the non-
volatile memory.
3
Once initialization of one-touch tuning is complete, the following window will be displayed. (for initializing to the initial value)
On a controller [G] [WG]
Writing "0000h" to [One-touch tuning Clear (Obj. 2D53h)] enables to return the servo parameter to the initial value.
Writing "0001h" to [One-touch tuning Clear (Obj. 2D53h)] enables to return the setting value of servo parameter to the value
before one-touch tuning. The setting value of the returned servo parameter is stored in the non-volatile memory.
3 ADJUSTMENT METHOD
35
3.2 One-touch tuning