Step Inputs - Keysight Technologies E5400-Pro Series User Manual

Soft touch connectorless probes
Table of Contents

Advertisement

Step Inputs

Logic
Analyzer
w/ EyeScan
Driver
Rsource
50 Ω
Keysight Technologies E5400-Pro Series Soft Touch Connectorless Probes User's Guide
Maintaining signal fidelity to the logic analyzer is critical if the analyzer is
to accurately capture data. One measure of a system's signal fidelity is to
compare V
in
the signal at the logic analyzer probe tip. Eye Scan was used to measure
V
, the signal seen by the logic analyzer. The measurements were made
out
on a mid-bus connection to a 50Ω transmission line load terminated at the
receiver. These measurements show the logic analyzer's response while
using the E5402A, E5405B, and E5406A-pro series soft touch probes.
E5382A
Probe
Step
output
Z0=50 Ω
Figure 35 Step input measurement schematic (E5402A, E5405B, and E5406A)
The following plots were made on a Keysight 54750A oscilloscope and a
Keysight 16760A logic analyzer using a Keysight 8133A pulse generator
with various rise time converters.
Operating the E5402A, E5405B, and E5406A-Pro Series Probes
to V
for various step inputs. For the following graphs, V
out
54701A
Probe
Z0=50 Ω
4
is
in
Oscilloscope
2.5GHz BW
incl. probe
Receiver
Rterm
50 Ω
57