Tag Locking

Tag locking is a two step process:
Write the tag access password (see
Lock the tag (see
Figure 7-11 on page
To write the access password first enter the access password of the tag:
Read the tag.
1.
Click on the tag, it appear in the EPC Mask field.The tag is now selected for operations.
2.
Write the access password for the tag:
3.
Select the Reserved memory bank as the target memory bank.
In the Data field write 32 bits of access password (e.g.: 22222222 in the Data field.)
Select User Offset as 2 (this is in words) of access password. To program kill password use User Offset 1.
The following entries should be on the screen:
4.
Reserved memory bank should be selected
User Offset field
Data field, this is the access password
EPC Mask field, the tag to write to
Click on Write.
5.
Once the user has been successfully able write Access password on the tag, the tag can be locked.
6.
To Lock the tag
Read the tag.
1.
Click on the tag, it appear in the EPC Mask field.The tag is now selected for operations
2.
Enter the access password values as programmed (in the case of this example 22222222) in the field next to
3.
Lock.
Select the EPC memory bank as the target memory bank to lock the EPC ID field.
4.
Select the Lock options, e.g.: EPC bank and Lock or permanently lock.
5.
The following entries should be on the screen:
6.
EPC memory bank should be selected
EPC Mask field, has the tag to write to
Lock, this has the Lock password
Lock Options have been configured
Click on Lock
7.
Tag is now locked.