3. Commissioning
Festo P.BE−CPX−CEC−EN en 1004a
Manual module configuration
Select [Append Subelement] if you want to perform
·
module configuration manually.
Attach the CPX modules from left to right in the physical
sequence on the CPX terminal. The modules are added at the
bottom in the tree structure. The CoDeSys controller sits in
the CPX terminal to the far left at position 0.
From the list of the CPX modules, select the CPX module
·
to the right of CPX−CEC−...
Repeat [Append Subelement] until you have selected all
·
CPX modules.
Addressing of inputs and outputs takes place automatically
(preset in the delivery condition of the device). For each mod
ule, at least 4 bytes of inputs or outputs are reserved.
The rotary switch of the CPX−CEC−C1, for example, occupies
only 4 bits of inputs, but 4 bytes are reserved.
Alternatively, you can also manually address the inputs
and outputs. Information can be found in the online help.
3. Save the project.