I/O Module; Drive; Figure 82 I/O Module Installation Order - Fujitsu ETERNUS DX60 S4 Design Manual

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX60 S4:
Table of Contents

Advertisement

3.
Hardware Configurations
Standard Installation Rules

I/O Module

This section describes the standard installation rules for I/O modules.
By installing I/O modules, the drive enclosure can connect with the controller enclosure even if drives are not
installed.
Installation Order
Install IOM#0 first, and then install IOM#1.

Figure 82 I/O Module Installation Order

I/O module 0 (IOM#0)

Drive

This section explains the installation rules for drives.
The supported drives vary between the ETERNUS DX60 S4 and the ETERNUS DX60 S3. For details about drives,
refer to "Overview" of the currently used storage systems.
2.5" Drives
The installation priority order for 2.5" drives is shown below.
1
2.5" SSDs (200GB)
2
2.5" SSDs (400GB) (MLC SSDs)
3
2.5" SSDs (400GB) (Value SSDs)
4
2.5" SSDs (800GB)
5
2.5" SSDs (960GB)
6
2.5" SSDs (1.6TB)
7
2.5" SSDs (1.92TB)
8
2.5" SSDs (3.84TB)
9
2.5" SAS disks (300GB/15krpm)
10
2.5" SAS disks (600GB/15krpm)
11
2.5" SAS disks (900GB/15krpm)
12
2.5" SAS disks (300GB/10krpm)
13
2.5" SAS disks (600GB/10krpm)
14
2.5" SAS disks (900GB/10krpm)
15
2.5" SAS disks (1.2TB/10krpm)
16
2.5" SAS disks (1.8TB/10krpm)
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Design Guide (Basic)
I/O module 1 (IOM#1)
Rear view of a drive enclosure
135
Copyright 2019 FUJITSU LIMITED
P3AM-8992-14ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx60 s3