1.
Function

Environmental Burden Reduction

Environmental Burden Reduction

Eco-mode

Eco-mode is a function that reduces power consumption for limited access disks by stopping the disks rotation
during specified periods or by powering off the disks.
Disk spin-up and spin-down schedules can be set for each RAID group or TPP. These schedules can also be set to
allow backup operations.

Figure 36 Eco-mode

Working Phase
12
Off
PM
(12:00 to 24:00)
SAS disk
Nearline SAS disk
Disks stopped
The Eco-mode of the ETERNUS DX is a function specialized for reducing power consumption attributed to Massive
Arrays of Idle Disks (MAID). The operational state for stopping a disk can be selected from two modes: "stop mo-
tor" or "turn off drive power".
The disks to be controlled are SAS disks and Nearline SAS disks.
Eco-mode cannot be used for the following drives:
Global Hot Spares (Dedicated Hot Spares are possible)
SSDs
Unused drives (that are not used by RAID groups)
The Eco-mode schedule cannot be specified for the following RAID groups or pools:
No volumes are registered
Configured with SSDs
RAID groups to which the volume with Storage Migration path belongs
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Design Guide (Basic)
Disk spin-up
Backup Phase
Off
(0:00 to 5:00)
SAS disk
Backup
Nearline SAS disk
Disks spinning
Control linked to usage
Backup disks spins
for five hours
58
Copyright 2019 FUJITSU LIMITED
Disk spin-down
12
On
5
AM
Working Phase
12
Off
AM
(5:00 to 12:00)
SAS disk
Nearline SAS disk
Disks stopped
P3AM-8992-14ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx60 s3

Table of Contents