Table 28 Volume Types That Can Be Used With Veeam Storage Integration - Fujitsu ETERNUS DX60 S4 Design Manual

Hybrid storage systems
Hide thumbs Also See for ETERNUS DX60 S4:
Table of Contents

Advertisement

1.
Function
Server Linkage Functions
The controller firmware version of the ETERNUS DX must be V10L86 or later.
The Veeam Storage Integration license must be obtained and registered in the ETERNUS DX.
iSCSI and FC host interfaces are supported in Veeam Storage Integration for the connection between backup
proxies and the ETERNUS DX.
To connect a Backup Proxy with the ETERNUS DX via an FC, the host affinity settings must be configured for
the Backup Proxy using ETERNUS CLI. For more details, refer to "ETERNUS CLI User's Guide".
To enable the ETERNUS DX storage snapshot integration with Veeam Backup & Replication, FUJITSU Plug-In
for Veeam Backup & Replication must be installed to the Veeam backup server.
If a volume has several snapshot generations and these snapshots have been created with different resolu-
tions, only the oldest snapshot generation can be deleted.
The following volumes cannot be managed or operated by Veeam Backup & Replication:
Volumes with Advanced Copy sessions except SnapOPC+ sessions
-
Volumes with SnapOPC+ sessions created by ETERNUS SF AdvancedCopy Manager
-
Veeam Backup & Replication jobs or operations may fail during a RAID migration or a Thin Provisioning Vol-
ume balancing.
SnapOPC+ is used for Veeam Storage Integration.
Thin Provisioning Volumes (TPVs) are used as SnapOPC+ copy destination volumes.
Configure an appropriate maximum pool capacity for the Thin Provisioning function by taking the total ca-
pacity of volumes used for Veeam Storage Integration and the number of snapshot generations into consid-
eration. For more details about the maximum pool capacity setting, refer to "Thin Provisioning Pool Man-
agement" in "ETERNUS Web GUI User's Guide".
Guidelines for the maximum pool capacity for the Thin Provisioning function:
Maximum pool capacity ³ total capacity of TPVs + total capacity of volumes for Veeam Storage Integra-
tion ´ (number of snapshot generations + 1)
It is not recommended to use multiple Veeam Backup & Replication for managing a single ETERNUS DX.
In such configuration, an error might occur at the jobs that are in conflict with each other when being exe-
cuted from multiple Veeam Backup & Replication.
Veeam Storage Integration supports the following volumes.

Table 28 Volume Types That Can Be Used with Veeam Storage Integration

Volume type
Standard
WSV
TPV
SDV
SDPV
¡: Supported ´: Not supported
Copy destination TPVs are automatically created when snapshots are created with Veeam Backup & Replica-
tion.
FUJITSU Storage ETERNUS DX60 S4, ETERNUS DX60 S3 Hybrid Storage Systems Design Guide (Basic)
Copy source
¡
¡
¡
´
´
91
Copyright 2019 FUJITSU LIMITED
Copy destination
´
´
¡
´
´
P3AM-8992-14ENZ0

Advertisement

Table of Contents
loading

This manual is also suitable for:

Eternus dx60 s3