Calibration - Protek A434L Operating Manual

4 ghz cable & antenna analyzer
Table of Contents

Advertisement

Stop Freq
5. Select the
6. Enter a stop frequency value.
7. Press the Enter key.
Selection from the band list stored in the instrument.
1. Press the Freq/Dist key.
Band List
2. Select the
3. Select the band from the list and
press the Enter key.
Changing the frequency settings will automatically turn
calibration off with the symbol "Cal Off" to be displayed on
the screen along with an alarm sound. In this case,
recalibrate the instrument with the Open-Short-Load Calibration kit.
4.3.3

Calibration

The instrument must be calibrated to get reliable Cable Loss measurement
results. For best results, set the frequency and calibrate the instrument
immediately before taking measurements.
Calibration accessories (optional)
Calibration Kit which contains one 50ohm load, one Open
standard and one Short standard
To minimize the measurement error in Cable Loss measurement, don't
use unnecessary extension cables or adapters while performing
calibration. Figure 4.13 illustrates the recommended calibration
method for Cable Loss measurement.
screen menu.
screen menu.
Table 4.4 Frequency Setting Procedure
window one by one.
Pressing the ESC repeatedly will
cancel the input mode.
Input unit is MHz and minimum
input step is 0.01MHz.
Page Up/Page Down
Select the
screen menu for searching the
band that doesn't show up on the
current page.
93