Dimensions Of Flue Gas Outlet Pipe - DeDietrich EVODENS PRO Series Installation And User Manual

High-efficiency wall-hung gas boiler
Table of Contents

Advertisement

4 Preparation of installation
Tab.12
Overview of material properties
Version
Flue gas outlet
Material
Single-wall, rigid
Plastic
Stainless steel
Thick-walled,
aluminium
(1) according to EN 14471
(2) according to EN 1856
(3) according to EN 13501-1
Fig.7
Dimensions of open connection
ød
1
Fig.8
Dimensions of parallel connection
ød
1
20
AMC Pro
Material properties
With CE marking
(1)
Temperature class T120 or
(2)
higher
Condensate class W (wet)
(2)
Pressure class P1 or H1
Fire resistance class E or bet­
ter
(3)
4.7.3
Tab.13
150 mm
AD-3001094-01
Tab.14
80/80 mm
100/100 mm
150/150 mm
øD
1
AD-3000963-01
Warning
The coupling and connection methods may vary depending on
the manufacturer. It is not permitted to combine pipes, coupling
and connection methods from different manufacturers. This also
applies to roof feed-throughs and common channels.
The materials used must comply with the prevailing regulations
and standards.
Air supply
Material
Plastic
Stainless steel
Aluminium

Dimensions of flue gas outlet pipe

Warning
The pipes connected to the flue gas adapter must satisfy the
following dimension requirements.
d
External dimensions of flue gas outlet pipe
1
Dimensions of pipe
d
(min-max)
1
149 - 151 mm
d
External dimensions of flue gas outlet pipe
1
D
External dimensions of air supply pipe
1
Dimensions of pipe
d
(min-max)
1
79.3 - 80.3 mm
99.3 - 100.3 mm
149 - 151 mm
Material properties
With CE marking
Pressure class P1 or H1
Fire resistance class E or bet­
ter
(3)
D
(min-max)
1
79.3 - 80.3 mm
99.3 - 100.3 mm
149 - 151 mm
7725131 - v.01 - 06062019