Product Specification - Mira Agile S B97C Installation And User Manual

Table of Contents

Advertisement

Product Specification

Technical Details
Temperature control
Control type: Thermostatic temperature control
Installation
Water entry points: rear only
Inlet connections: 15 mm copper pipe
Outlet connections: ½" BSP Male Flat Face
Reversed inlets supported: No = hot left, cold right only
Supply Conditions (hot and cold)
Cold water range: 1°C to 25°C
Hot water range: 55°C-65°C (recommended for optimum performance)
Minimum maintained pressure: 0.1 bar (1 metre head)
Maximum maintained pressure: 5.0 bar (50 metre head)
Maximum static pressure: 10.0 bar (100 metre head)
For optimum performance supplies should be nominally equal.
Dimensions
80 mm
50 mm
45 mm
50 mm
58 mm
133 mm
www.mirashowers.co.uk/expert
61 mm 44 mm
83 mm
Performance
Flow rate (at handset): Agile S EV, 10 l/min at 0.5 bar;
Agile S Eco EV, 6 l/min at 0.5 bar; Agile EV+, 11 l/min at 0.5 bar
Temperature stability: ± 2°C
Safety Features
Automatic shutdown: Shutdown within 2 secs should either supply fail
Factory set to safe max temp: Factory set to 43°C
Approvals
KIWA UK approved product
WRAS approved (Water Regulations Advisory Scheme)
Buildcert TMV2 Approved
562 mm
310 mm
510 mm

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Agile s eco b97cAgile store ev+ b97dAgile ev+ b97cAgile erd+ b97dAgile sense erd+ b97d