Commissioning
Before using the shower, the maximum temperature must be checked to make sure that it is
at a safe level. It has been preset to a safe showering temperature under ideal conditions at
the factory, appropriate for most systems. However, site conditions and personal preference
may make it necessary to reset this temperature.
Note: Make sure that the hot water temperature is at least 55° C and that there is sufficient
supply.
Make sure that all users are familiar with the operation of the shower. This guide is the
property of the homeowner.
Note: For Type 2 installations the maximum temperature is determined by application, refer
to the TMV2 Requirements Manual.
If you experience any difficulty with the operation of your new shower, then please refer to
"Fault Diagnosis", before contacting our customer services department.
Flow and Temperature Check
1.
Turn the shower on and check the temperature adjustment operates correctly. (Allow a
few seconds for any temperature adjustment to take effect.)
2.
Turn to maximum temperature (full hot) and allow the temperature and flow to
stabilise.
3.
Turn the shower off.
Maximum Temperature Adjustment
1
Pull the control lever from the body then
remove the retaining screw with a 2.5 mm
hexagonal key.
=
2
Pull the stop assembly from the body.