Temperature-Limit - H3C S7500 Series Command Manual

System maintenance and debugging
Hide thumbs Also See for S7500 Series:
Table of Contents

Advertisement

Command Manual – System Maintenance and Debugging
H3C S7500 Series Ethernet Switches
After you execute the command, the system will prompt you to confirm. Enter "Y" or "y"
for your setting to take effect. Your setting will overwrite the old one (if available).
If you adjust the system time by the clock command after executing the schedule
reboot delay command, the schedule reboot delay command will be invalid and the
scheduled reboot will not happen.
Related commands: reboot, schedule reboot at, undo schedule reboot, display
schedule reboot.
Examples
# Suppose the current time is 16:26, schedule a reboot so that the switch reboots after
88 minutes.
<H3C> schedule reboot delay 88
Reboot system at 17:54 2005/04/06(in 1 hours and 28 minutes)
confirm?[Y/N]:y
<H3C>
%Apr
6 16:26:38 2005 S7506R CMD/5/REBOOT:
aux0: schedule reboot parameters at 16:26:34 2005/04/06. And system will reboot
at 17:54:2005 04/06/2005.

3.1.24 temperature-limit

Syntax
temperature-limit slot-number down-value up-value
undo temperature-limit slot-number
View
User view
Parameters
slot-number: Physical card slot number.
down-value: Lower temperature limit, ranging from 0 to 70, in centigrade.
up-value: Upper temperature limit, in centigrade, ranging from 20 to 90, and must be
greater than the down-value.
Description
Use the temperature-limit command to configure temperature alarm threshold.
Use the undo temperature-limit command to restore temperature alarm threshold to
the default.
By default, the lower temperature limit is 20, and the upper limit is 80.
Chapter 3 Device Management Commands
3-18