I/O-Bus
5 - 24
Table 36: LED Control Register Access on 60x-Bus
Device
Size
LED control
512 Byte
Note:
•
If an LED is set to red and green at the same time, the respective LED
lights up yellow.
•
After any reset, the LED register is also reset, resulting in the front panel
LEDs lighting up yellow.
Table 37: LED Control Register
Address: F00A0000
16
Bit
Signal
7 (LSB)
L1 red
6
L1 green
5
L2 red
4
L2 green
3
L3 red
2
L3 green
1
L4 red
Width
60x Bus Address
8 bit
Programmable
(default:
F00A0000
)
16
Description
LED 1 lights red
0: LED on (default)
1: LED off
LED 1 lights green
0: LED on (default)
1: LED off
LED 2 lights red
0: LED on (default)
1: LED off
LED 2 lights green
0: LED on (default)
1: LED off
1)
L3 lights red
0: LED on (default)
1: LED off
1)
L3 lights green
0: LED on (default)
1: LED off
1)
L4 lights red
0: LED on (default)
1: LED off
Memory Map and Devices
Controlled by Line
CS8
Access
w
w
w
w
w
w
w
PPC/PMC-8260/DS1