Routing Time Division Multiplex Timeslots
TDM Channel Configuration
As is shown in the following figure the four output TDM streams C2/D2_TXD and
LDO_10/11 of the PMC-8260/DS1-H110 in the upper PMC slot 2 position are
cross-routed to the four TDM input streams C2/D2_RXD and LDI_10/11 of the
PMC-8260/DS1-H110 in the lower PMC slot 1. The same applies to the clock out-
put and the frame pulse output signals.
In the other direction (from the lower PMC slot 1 to the upper PMC slot 2) four ad-
ditional TDM output streams and two clock signals are cross-routed via the carrier
board to the four TDM input streams and two clock inputs of the upper PMC slot 2.
Note: The inter-TDM link is only available on H.110 variants but not on SC-
F variants.
Figure 21: Connection of Data Lines in Inter-TDM Link