Electrical installation
2
P_SI_0010_SW
Fig. 18: Pump pin assignments
Identity code 1 + 3 or 6 + 7
P_SI_0043
Fig. 19: Cable conductor assignments

9.3.2 Output for other relays (identity code 4 + 5, 8 + 9, A + B)

2
P_SI_0010_SW
Fig. 20: Pump pin assignments
36
Electrical interface
Data
Maximum contact load at 230 V and 50/60
Hz:
3
1
Minimum mechanical lifespan:
4
To pin
1
2
4
A fault indicating and a pacing relay can optionally be ordered - refer to
ordering information in the appendix. The pacing output is electrically-iso‐
lated by means of an optocoupler with a semiconductor switch. The
second switch is a relay.
The behaviour is programmed ex factory. If another switching function is
required, the pump can be reprogrammed in the
The fault indicating/pacing relay can be retrofitted and is operational once
attached to the relay board - refer to "Retrofitting Relays" supplementary
operating instructions.
Electrical interface
for fault indicating relay output:
Data
3
Maximum contact load at 24 V and 50/60
1
Hz:
4
Minimum mechanical lifespan:
for semiconductor switch pacing relay:
Data
Residual voltage max. at I
Maximum current
Maximum voltage
Pacing pulse duration, approx.
VDE cable
Contact
white
NO (normally open)
green
NC (normally closed)
brown
C (common)
= 1 µA
off max
Value Unit
8 A
200 000 Switching
operations
CSA cable
white
red
black
'Relay' menu.
Value Unit
2 A
20,000,000 Switching
operations
Value Unit
0.4 V
100 mA
24 VDC
100 ms