7-4 Technical specifications
Table 7-4
Power consumption for each circuit pack at -54 V dc
Circuit pack
8x10/100BT L1
2xGE L1
3xE3/DS3
28xE1/DS1
2x155M
Table 7-5
Power consumption for each SFP at -54 V dc
STM-1/4 and GE SFP modules
STM-1 SR0 (multimode)
STM-1/4 S1.1/4.1
STM-1/4 L1.1/4.1
STM-1/4 L1.2/4.2 XCT
STM-1/4 CWDM
STM-1 (100Base) Bidirectional at 1310nm
STM-1 (100Base) Bidirectional at 1550nm
STM-1e (electrical)
GE SX
GE LX
Table 7-6
Recommended feeders
Configuration
OME6130 chassis with
DC PSU
Refer to
and the Installation, Commissioning and Testing Procedures, 323-1855-201
for details on installing and connecting power to an OME6130 shelf.
Optical Multiservice Edge 6130
Feeders per shelf
A feed (6 A) and redundant B feed (6 A)
Table 8-20 on page 8-18
NT6Q92MA Rel 1.0 Iss 1 Standard September 2006
Typical
(W)
7.6
8
8
7.2
8
for a list of power cables assemblies available
Typical
(W)
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7
0.7